The data centers are 24 / 7 manned by a security service. A powerful camera monitoring of the the entrance as well as of the the outdoor and indoor facilities will ensure that no unauthorized persons will be in the Technical Services area.

Power

The permanent power supply is ensured by a sophisticated redundancy concept of multiple power suppliers with multiple, non-crossed cable routes. However, should the power fail, a UPS (uninterruptible power supply) takes care, that all major components are supplied with power, until emergency power generators to take over the operation. For reasons of stability, several emergency power generators were installed.

Our Data Center

Our projects are hosted in Germany

All servers in nunodesign are hosted electively in Frankfurt am Main or Nuremberg. The data center in Frankfurt is one of the most modern in the world and even satisfies the high safety standards of major european banks.

The data center is designed to be fully redundant, all functions are continuously monitored and numerous safety systems protect servers from unauthorized access. All nunodesign servers are in highly secure environment and are protected from dust, moisture, fire and fire water. Special door systems, video surveillance and a private security service provide an effective, seamless burglary around the Clock.

Specific access controls

Photo identification systems, biometric palm scanners and card systems to all internal doors allow only authorized access to data centers entered. The entrance gates with security glass and steel walls in the entrance and exit area complete the integrated security of the data centers.

Fire safety

Two-step detection systems and three-stage fire safety provide the operation even in case of fire. The smoke detection system (SDS) and the decentralized automatic fire extinguishing system (Marioff Hi-Fog system) prevent in time that life-support systems, data centers and hardware be damaged in a fire.

Air conditioning

The air conditioning in data centers is based on the principle of N+1 redundancy at full load. All modules have a standby compressor and are alternately supplied by a redundant climate cycle (A and B). Each circle has a current and a standby pump. There are only about 75% of the available cooling power capacity needed, to operate the data center under full load.